Facility Name
|
Medfly Facility
|
|
Insect Reared
|
Ceratitis capitata
|
|
Type of irradiation source
|
Co60
|
|
Model
|
Model 1 =?
Model 2 =?
|
|
Initial capacity (Ci)/date
|
Model 1:(3.7 PBq) 100 KCi/1999 40 KCi/2005 Model 2:18000 Ci/2002 12 KCi/2005
|
|
Type of dosimetry
|
Gafchromic film (routine) Fricke dosimeter (reference position
|
|
Frequency of dose measurement
|
each treatment
|
|
Radiosterilization dose (Gy)
|
140 Gy
|
|
Dose rate (Gy/hour)/date
|
Model 1: on the turn plate: 30Gy/mn On the table 10 Gy/mn Model 2:100Gy/mn
|
|
Temperature before irradiation (°C)
|
16°C
|
|
Temperature at irradiation (°C)
|
ambient
|
|
Atmosphere condition
|
Air
|
|
Time of anoxia before irradiation (min)
|
2 hours
|
|
Stage of insect treated
|
|