The design of a nuclear fuel cycle facility shall apply the concept of defence in depth. The levels of defence in depth shall be independent as far as is practicable.
6.19.
The defence in depth concept shall be applied to provide the appropriate number of levels of defence to prevent accidents and to ensure that appropriate measures are taken to mitigate harmful consequences if prevention fails [1, 15].
6.20.
The continued operation of the facility during the unavailability of any of the levels of defence shall be justified for specific modes of operation including maintenance operations, with account taken of the safety classification of the structures, systems and components providing the remaining levels of defence.
6.21.
The design of the nuclear fuel cycle facility:
Shall provide for successive verifiable barriers to fulfil the main safety functions listed in Requirement 7.
Shall use conservative margins, and manufacturing and construction shall be of high quality so as to provide assurance that failures and deviations from normal operation are minimized and that accidents are prevented as far as is practicable. Safety margins shall be sufficient to ensure that a small deviation in a facility parameter does not lead to a cliff edge effect.
Shall provide for the control of facility behaviour by means of inherent and engineered features, such that failures and deviations from normal operation requiring the actuation of safety systems are minimized or excluded by design, to the extent possible.
Shall provide for supplementary controls for the facility by means of automatic actuation of safety systems, such that failures and deviations from normal operation that exceed the capability of control systems can be controlled with a high level of confidence. Whenever operator actions are necessary in such events, the actions shall only be credited in the early phase of the failure of a safety system if it can be ensured that the operator will have sufficient time to take the necessary actions.
Shall provide for structures, systems and components and procedures to control the course of and, as far as practicable, to limit the consequences of failures and deviations from normal operation that exceed the capability of safety systems.
Shall provide reliable means for ensuring that each of the main safety functions is performed, thereby ensuring the effectiveness of the items important to safety and the procedures that prevent an event progressing or that mitigate its effects. These means provided shall be diverse and independent where possible, e.g. static and dynamic barriers providing confinement (see Requirement 23).
6.22.
The design shall prevent, as far as is practicable:
Challenges to the integrity of physical barriers and to the reliability of procedural levels of protection;
Failure of one or more barriers or levels of protection;
Failure of a barrier or level of protection as a consequence of the failure of another barrier or level of protection, and common cause failures;
The possibility of harmful consequences of errors or omissions in operation and maintenance.
6.23.
Depending on their safety classification, the structures, systems and components providing different levels of defence in depth shall be independent to avoid a failure of one level reducing the effectiveness of other levels. In normal operation, items important to safety shall not routinely be activated or challenged or shall be challenged only with a very wide safety margin.
6.24.
The safety analysis for a nuclear fuel cycle facility shall extend to the fourth and fifth levels of defence in depth. The design of the facility shall include provisions for emergency preparedness and response (Requirement 47), including the necessary emergency power supply (Requirement 49), provisions for fire protection (Requirement 41) and provisions for the evacuation of personnel in an emergency, in accordance with the emergency preparedness category of the facility. The need for operator actions before evacuation (to prevent fire, criticality, explosion or toxic release) shall be considered in the analysis and appropriate protection for personnel shall be provided.
6.25.
As far as practicable, emergency response facilities shall be independent of the facilities used for normal operation. Where appropriate, a separate emergency response facility shall be provided (see Requirement 48).
6.26.
Where off-site protective actions could be necessary to achieve the goals of emergency response in accordance with international standards, emergency arrangements shall be established for postulated events that have not been considered in the first, second or third levels of defence in depth, including events that have occurred in other facilities in the same emergency preparedness category (see table 1 in GSR Part 7 [6]). For multifacility sites, the potential interaction with or impact from accidents at other facilities on the same site shall be considered in the analysis of the fourth and fifth levels of defence in depth.
6.27.
Defence in depth shall be applied taking into account a graded approach, as described in Section 2 and Requirement 11. The amount and type of radioactive material and toxic material present, their potential for dispersion, the potential for nuclear, chemical or thermal reactions, and the kinetics of such events shall all be considered in determining the required number of levels of defence, the strength of each level of defence and their independence from each other.