Sources of Radiation and Source Terms During Normal Operation and Decommissioning of a Nuclear Power Plant

empty

I–48.

The radiological consequences of normal operation and decommissioning include impacts on persons and the environment that are attributable to both direct radiation and the releases of radioactive materials from the plant. The sources of radiation include sources at the site and also discharges from the site. In the assessment of the radiological impact, all pathways of external exposure are to be assessed, including direct ionizing radiation from buildings and from transportation, from gaseous and liquid discharges from the facility, and from any deposition of radionuclides on the ground or other surfaces. Internal exposure from inhalation or ingestion of radionuclides are also to be assessed.

empty

I–49.

The most significant radionuclides in terms of doses to site personnel and members of the public are usually the isotopes of the noble gases iodine and caesium, but others such as the isotopes of strontium and plutonium may also be important. When the reactor is at power, the fuel elements emit neutron and gamma radiation as a result of the fission process and the decay of fission products. Gamma rays are also emitted as a result of neutron capture in the core and the surrounding material. Other forms of radiation such as beta particles and positrons are emitted from the core and the vessel region during power operation, but these are not important for the purposes of radiation protection because of the limited penetration range of these charged particles.

empty

I–50.

Fission products such as 131I, 134Cs and 137Cs make a small contribution to dose rates around the reactor coolant circuits because the source term is small and the deposition rate is low. However, their contribution to dose rates can increase significantly in situations where components such as heat exchangers and valves are opened or entered for maintenance and repair.

empty

I–51.

If a reactor continues to operate with significant fuel cladding defects, a non‑negligible mass of fuel (a few grams to a few tens of grams) might be released into the coolant. In this situation, the alpha activity of the water and of the deposits might not be negligible (the alpha emitters, mainly in particulate form, deposit quickly). Together with fission and corrosion products, it is an important potential source of internal exposure when circuits and components are opened for maintenance and repair. It is also a potentially important source during decommissioning.

empty

I–52.

The main contributors to dose rates during maintenance and repair are activated corrosion products, such as 60Co, 58Co, 110mAg, 124Sb, 54Mn, 59Fe and 51Cr. These are present as deposits on all the components and pipes of the primary coolant circuit and the circuits that are connected to it.

empty

I–53.

In the case of pressurized water reactors with nickel based materials in the steam generators, important phenomena occur during the period when the reactor is brought from operation at power to a cold shutdown state, namely involving major changes in the physical (temperature, pressure) and chemical (from reducing to oxidizing conditions, pH) conditions. The solubility of deposited oxides of corrosion products and metallic species increases considerably. A large proportion of the activated corrosion products deposited on the fuel are released to the coolant, and the activity concentration of the water might be increased by two or three orders of magnitude. The release rate is not constant, and it decreases when the temperature is decreased from hot conditions to 80°C. The release increases sharply when peroxide water is injected, and a spike is observed (especially for 58Co). After the spike, the evolution of the activity concentration of water is determined by the purification constant (i.e. the ratio of the purification flow rate to the mass of water). The dissolution of deposits outside the core is generally negligible. No decontamination of these components (primary pipes, steam generator, pumps) is therefore observed. The corrosion products of high activity that are removed after the spike occurs accumulate mainly on the ion exchangers of the chemical and volumetric control system. The activity may be equal to the total activity accumulated on the fuel during the operational period. These phenomena are greatly influenced by the design (mainly the composition of the alloy in the steam generator tubes, which may be nickel or iron based). During this period of primary coolant purification, the contribution of radioactive material in the water to dose rates around the reactor coolant system, chemical and volume control system and residual heat removal systems is not negligible in comparison with the contribution of the deposits. During purification, recontamination of the out‑of‑flux surfaces can be observed (e.g. 58Co in steam generators, 110mAg on cold parts of the circuits, such as the non‑regenerative heat exchanger). After purification, the main contributors to the dose rates are the activated corrosion product deposits.

empty

I–54.

The neutron and gamma radiation emitted by the core represent a very intense source of radiation. The residual neutron flux outside the primary shielding is a source of activation of structural materials. It can therefore induce a buildup of supplementary sources with associated dose rates during shutdown periods and will be a major source of radiation during the decommissioning of the plant.

empty

I–55.

Other sources (including 41Ar, airborne contamination by 3H and volatile fission products and rare gases) need to be considered when access to the reactor building is permitted during the operation of the reactor. In a pressurized water reactor, the activation of 40Ar contained in the air is a source of 41Ar, which is a gamma radiation emitter. The ventilation of the reactor cavity results (in some designs) in the 41Ar contamination being transferred to the whole free volume of the reactor building above the operating deck. Although the corresponding dose rate (external exposure) is low, it might not be negligible when the individual dose rate target is less than 10 µSv/h. Tritium is also an important possible source of airborne contamination in heavy water reactors and in the fuel building of a light water reactor. Argon‑41 is also produced in the CO2 coolant of gas cooled reactors and in the systems of heavy water reactors that contain helium gas, such as the liquid zone control system and the moderator cover gas system. In pressurized water reactors, if the coolant temperature is not properly controlled, its reduction can result in significant iodine plate‑out on reactor coolant piping. Such iodine can be released as airborne contamination during shutdown, when the primary circuit is drained down. Iodine ‘hideout’ can become airborne and result in significant airborne contamination levels in the containment. This is the case even with low levels of fuel failure.

empty

I–56.

After shutdown of the plant, the main radiation source in the vicinity of the vessel is the gamma radiation from the fission products and activation products created in the vessel, in the metallic parts of the insulation and in any material that has been exposed to the neutron flux for a sufficiently long time. For some designs of heavy water reactor, neutrons produced by subcritical multiplication of the photoneutron source give rise to a significant power level accompanied by gamma radiation for a short period of time (about 24 hours).

empty

I–57.

In cases where there is a separate oxygen containing fluid moderator system (e.g. in a pressure tube reactor), the isotope that is the major source of radiation during reactor operation is 16N. After shutdown, the radiation levels around the primary coolant system are due mainly to activated corrosion products. The tritium present in the water coolant or moderator contributes to the radiation hazard only if it is released from the system and becomes airborne. This also has to be taken into account in the design of light water reactors, since operation with a limited leakage of primary coolant is tolerated.

empty

I–58.

In direct cycle water reactors, 16N, which is carried over to the steam phase, is the major source of radiation during power operation. The sky shine effect needs to be carefully checked for buildings with potentially light structures, such as the roof of the turbine building or of the pressure suppression containment. Downstream from the condenser, 19O also needs to be considered a major source of radiation. In the event of fuel pin failures, an additional source of radiation is volatile fission products, mainly the noble gases, and volatile fission products such as iodine and caesium. During power operation, this source is of minor importance compared with 16N, but after reactor shutdown these isotopes and their progeny (e.g. 140Ba) will be the major radiation source in this system. Another source may be non‑volatile corrosion products that are carried over with water droplets in steam.

empty

I–59.

Carbon‑14 is produced in light water reactors and heavy water reactors by (n, α) reactions with the 17O present in the oxide fuel and moderator, by (n, p) reactions with the 14N present in impurities in the fuel and by ternary fission. Because of the large moderator mass, 14C is produced mainly from 17O reactions in the moderator in heavy water reactors. This may be the main source term for this nuclide and a contributor to the global long term collective dose. However, in some heavy water reactor systems the contribution of 14C to the total collective dose is relatively small because 14C is effectively removed from the moderator by the purification system.

empty

I–60.

The coolant of some gas cooled reactors contains 35S in the form of carbonyl sulphide, tritium and 14C. The 35S is produced mainly from the chlorine impurity in the graphite moderator, the tritium from the lithium impurity in the graphite and 14C from the nitrogen impurity in the coolant and moderator. Because these are pure beta emitters, they present a radiation hazard only if inhalation or ingestion is possible.

empty

I–61.

For fast breeder reactors with sodium coolant, the dominant sources are 22Na and 24Na. Sodium vapours may rise into primary components. If these components penetrate the shield, considerable shielding is needed to yield acceptable dose rates on the operating floor. Tritium that is generated in the fuel by ternary fission is released to the primary coolant through the stainless steel cladding of the fuel (the principal mechanism is diffusion). The sodium coolant can be covered by an inert gas such as argon. The activation of the cover gas gives rise to 39Ar and 41Ar, which might leak into the reactor building.

empty

I–62.

In pressurized water reactors and pressurized heavy water reactors, provision needs to be made for cleaning the fluid circuits and for waste disposal from the secondary side in case primary to secondary leaks occur. The leakage of primary coolant to the secondary circuit can also be detected by monitoring tritium in the feedwater. The presence of radioactivity in the feedwater can lead to the uncontrolled release of radioactive material to the environment through feedwater leaks as well as the venting of steam.

empty

I–63.

Increasing the delay time reduces the content of short lived isotopes in the effluent but does not significantly alter the content of isotopes with half‑lives longer than the delay time. However, the increase of the delay time to 30 days considerably reduces the release of the rare gas effluents, particularly 133Xe. In this case, the most important radionuclides released are 85Kr and 14C.

empty

I–64.

The ventilation of buildings might be a source of gaseous release and, to a lesser extent, aerosols. The main isotopes are 3H (from evaporation of the pools) and 41Ar.

empty

I–65.

In some cases, it is not possible to prevent the dilution of radioactive gases with inactive gases such as air before they are processed. Examples of this are as follows:

  1. The calandria vault gas (in pressure tube reactors).

  2. The cover gases of containers in which liquids with some content of volatile substances are stored (e.g.storage tanks for collected reactor coolant leakage water in light water reactors and storage tanks or some other equipment in the liquid waste treatment system). In some cases, gases are formed by decay (e.g. the decay of iodine to xenon).

  3. Coolant gas leaking into sections that contain air in gas cooled reactors.

  4. Air that has entered the pressure vessel of a light water reactor after it has been depressurized and the water level has been lowered prior to opening the vessel.

Vents for these gases need to be located such that the radioactive material they contain is kept away from operating personnel. In the case of advanced gas cooled reactors and the calandria vault gas of pressure tube reactors, the radioactive material is mostly 41Ar. In the case of light water reactors, fission product gases usually dominate. In pressure tube reactors, the same is true for process vents that are in direct contact with coolant (e.g. in storage tanks).

empty

I–66.

During the handling and storage of irradiated fuel, some radionuclides are released to the surrounding coolant. Radioactive corrosion products might go into solution or be released as particles while the fuel is being transported or stored in water, or if part of the fuel route is dry, and particularly if the cladding is oxidized, activated material might flake from the surface of fuel assemblies as a result of thermal or mechanical shock. In addition, defective fuel might release fission products, of which isotopes of noble gases, iodine, caesium and strontium are the most significant.

empty