Fault tree analysis

empty

5.72.

Fault trees can be used to provide a complete logical failure model for all the credited system failure states identified by the event tree analysis.

empty

5.73.

The failure criterion that provides the top event of the fault tree for each safety function should be the logical inverse of the success criterion for the accident sequence specified in paras 5.50–5.58. In some cases, more than one fault tree model may be necessary for the same credited system to address the success criteria specified for different groups of initiating events or in different branches of the event tree, depending on the sequence of events prior to demand for the system. This can be done by developing different fault tree models or by using logical switches (known as house events) to disable or enable the appropriate parts of the fault tree model, depending on the success criterion.

empty

5.74.

The basic events modelled in the fault trees should be consistent with the available data on component failures. The component boundaries and component failure modes as modelled in the fault trees should be consistent with those defined in the data on the component failures. This is equally valid for both active and passive components.

empty

5.75.

The fault tree models should be developed to the level of significant failure modes of individual components (e.g. pumps, valves, diesel generators) and individual human errors and should include all the basic events that could lead, either directly or in combination with other basic events, to the top event of the fault tree. The level of detail of the analysis is generally determined by the analysts, but it should be sufficient to capture the possible dependencies and it should be consistent with the available data on component failures and the proposed applications of the Level 1 PSA.

empty

5.76.

The set of basic events to be modelled in the fault trees should be identified by means of systematic analysis (e.g. by means of a failure mode and effects analysis that has been carried out as part of the design assessment to identify important component failure modes) and through a review of actions by operating personnel supported by task analysis to identify potential human errors.

empty

5.77.

The fault tree model should include all components of the credited system that need to be operational, including support system components. It should also include passive components whose failure could affect the operation of the system (e.g. filter blockages, pipe leaks). The fault tree model should be developed in a way that ensures that dependencies are explicitly taken into account. Omitting the explicit modelling of these dependencies might significantly bias the results and lead to an underestimation of the relative importance of the support systems.

empty

5.78.

The degree of resolution of the components in the fault tree should be sufficient to ensure that all hardware dependencies can be modelled. For example, where the same system provides cooling water to a number of components, this cooling water system should be modelled explicitly. Available data on component reliability should also be taken into account when defining the degree of resolution. For example, reliability data might be available for a pump as a whole, but not for its constituent parts, such as the rotating wheel, coupling and bearing. In addition, when defining the degree of resolution of the components in the fault tree, consideration should be given to insights from the PSA in terms of the risk importance of plant equipment or of individual parts of equipment.

empty

5.79.

Where individual components are grouped together and a composite event is used to model their failure, it should be demonstrated that the failure modes of each component in the composite event have the same effect on the system as the composite event itself. In addition, all the composite events included in the model should be functionally independent (i.e. no individual component should appear in more than one composite event, or elsewhere as a basic event).

empty

5.80.

The fault tree models should take account of individual components or trains of equipment in the credited systems that might be taken out of service for testing, maintenance or repair in the course of the lifetime of the plant. Such components or trains of equipment should be identified and modelled explicitly in the fault tree analysis. This can be done, for example, by including basic events in the fault trees to represent component outages.

empty

5.81.

The unavailability of systems owing to testing and maintenance should be modelled in a way that is consistent with plant technical specifications20, with testing and maintenance practices at the plant and with operating experience, if available.

empty

5.82.

A system for uniquely coding or labelling each of the logic gates and basic events in the fault tree models should be developed, and this system should be used consistently throughout the complete logic model developed for the Level 1 PSA.

empty

5.83.

The development of the model should be consistent with the proposed applications of the Level 1 PSA. For example, if the Level 1 PSA is to be used for a risk monitor application, the model should be symmetrical so that it explicitly models initiating events in all locations in which they can occur, including all primary circuit loops, all trains of the credited systems, and all running and standby trains of normally operating systems. The development of a symmetrical model will allow the importance measures calculated by the Level 1 PSA code to be used in a straightforward manner (see para. 5.171 for examples of importance measures).

empty